搜索结果: 1-15 共查到“生物医学工程 monitoring”相关记录17条 . 查询时间(0.125 秒)
Wearable Sensor Smooths Path to Long-Term EKG, EMG Monitoring
Wearable Sensor Long-Term EKG EMG Monitoring
2015/3/4
Researchers from North Carolina State University have developed a new, wearable sensor that uses silver nanowires to monitor electrophysiological signals, such as electrocardiography (EKG) or electrom...
Comparison of Glycated Albumin (GA) and Glycosylated Hemoglobin (A1C) in monitoring glycemic excursions during pregnancy
GDM NGT GA A1C GW MNT BMI
2013/1/31
Objective: To compare GA with A1Cin monitoring glycemic excursions during pregnancy. Research Design and Methods: This study included 30 women with Gestational Diabetes Mellitus (GDM) and an equal num...
Intraoperative Nerve Monitoring in Otolaryngology: A Survey of Clinical Practice Patterns
Monitoring Intraoperative Mastoid/Surgery
2013/1/29
Introduction: Intraoperative nerve monitoring is used in otolaryngology to assist in identification of nerves at risk. It is hoped that this will lead to lower rates of nerve injury. The objective of ...
Tongue Laceration during Neurophysiologic Monitoring with Motor Evoked Potentials
Neuromonitoring Airway Injury Bite Blocks
2013/1/30
Although considered a safe modality for monitoring spinal cord function, motor evoked potentials (MEP) may cause tongue laceration in rare cases. Bite blocks are essential in order to prevent tongue a...
The Use of RIDA®COUNT for Monitoring the American Foulbrood Pathogen
AFB Apis mellifera L. Bacterial Disease Diagnosis Diseases of Honeybees
2013/2/19
American Foulbrood (AFB) is currently one of the most dangerous diseases in honeybees due to its high virulence and worldwide spread. Quick evaluation of the diagnosis of this disease is crucial. Succ...
The Monitoring Interest of BK Virus Load in Renal Allograft Tunisian Recipients: Prospective Study
BK Virus Renal Transplantation Urine and Plasma Viral Load Allograft Dysfunction
2013/1/31
BK virus (BKV) may cause nephropathy in renal transplant recipients receiving immunosuppressive therapy, resulting in renal dysfunction and, possibly graft loss. However, the positive and negative pre...
Real-time Monitoring of Force Response Measured in Mechanically Stimulated Tissue-Engineered Cartilage
Chondrocytes Poly(ethylene glycol) Mechanical stimulation Tissue engineering Biomechanics
2010/1/7
Mechanical stimulation improves tissueengineered
cartilage development both in terms of biochemical
composition and structural properties. However,
the link between the compositional changes attrib...
Design of a multi-axis implantable MEMS sensor for intraosseous bone stress monitoring
bone stress skeletal trauma bone quality
2009/12/23
The capability to assess the biomechanical properties of living bone is important for basic
research as well as the clinical management of skeletal trauma and disease. Even though
radiodensitometric...
Monitoring of Daily Living Based on the Level of Daily Activities
Physical activity Posture monitoring Action monitoring Acceleration sensor Neural network
2009/6/1
In the field of rehabilitation or care, it is extremely important that medical staff clearly understand the appearance of daily activities of the subjects to make and improve rehabilitation programs o...
Control Method of Local Density in Fluid Microcapsules by Acoustic Standing Wave and its Monitoring
ultrasound DDS microcapsule acoustic standing wave echogram artificial blood
2009/6/1
We have developed control method of local density in fluid microcapsules to make use of ultrasound drug delivery system. It has been difficult to enhance the efficiency of medication because capsules ...
A New Method for the Fast Determination of a Servo-Reference Value with Vibration Technique for Monitoring Non-Invasive Instantaneous Blood Pressure Using the Volume-Compensation Technique
Omron Healthcare Co.,Ltd.Product Strategy HQ Graduate School of Natural Science and Technology,Kanazawa University
2009/6/1
To perform the instantaneous radial blood pressure measurement based on the volume-compensation method, a reference value for the servo control (V0) has to be determined in the initial stage of the me...
Ambulant Long-term Monitoring of Activity and Body Temperature
Ambulant Long-term Monitoring of Activity Body Temperature
2009/6/1
Ambulant Long-term Monitoring of Activity and Body Temperature.
Monitoring of Oxygen Saturation during Sleep.
Measurement and monitoring of electrocardiogram belt tension in premature infants for assessment of respiratory function
electrocardiogram belt tension premature infants respiratory function
2010/2/26
The mechanical and electrical design of a device for monitoring electrocardiogram electrode belt tension is described. Within the typical range of application tension, cardiovascular and respiratory f...
Monitoring and analysis of dynamic growth of human embryonic stem cells: comparison of automated instrumentation and conventional culturing methods
dynamic growth human embryonic stem cells automated instrumentation conventional culturing methods
2010/2/26
In our analyses, hESC colony growth could be continuously monitored and the proportion of undifferentiated cells automatically analyzed. No labeling was needed and we could, for the first time, perfor...